| MR411 - 600A maximum | SR759 - 1200A maximum |
| SL261 - 100A maximum | JM875 - 3000A maximum |
| MR520 - 1500A maximum | FP300A - 300A maximum |
| MN255 - 240A maximum | FP3000A - 3000A maximum |
| FP6000A - 6000A maximum |
MR411 AC/DC Current Probe
Specifications:![]() The MR411 is a general purpose 400AAC or 600ADC current probe designed for use with Astro-Med recorders and data acquisition systems. The MR411 offers dual ranges of 40 and 400AAC or 60 and 600ADC. Nominal Range: 400Aac / 600 Adc Measurement Range: 0.2 to 600A Output Signal: 60A: 10mV/A 600A: 1mV/A Accuracy: Range dependent. See datasheet for details. Frequency Range: DC to 10 kHz @-3dB Max. Conductor Size: One 1.18-inch (30mm), or two 0.95-inch (24mm), or two bus bars 1.2 x 0.4-inch (31.5 x 10mm) Portable Operation Rating: Approximately 50 hours with alkaline battery Part Number: 24661200 Request Datasheet for MR411 current probe |
back to top
SL261 AC/DC Current Probe The Model SL261 is a portable 100A peak current probe that can accurately measure AC or DC current waveforms. The unit has proportional mV output for direct readings to |
back to top
MR520 AC/DC Current Probe The MR520 is a general purpose 1500AAC or DC current probe designed for use with Astro-Med recorders and data acquisition systems. The MR520 is a single range probe. |
back to top
MN255 AC Current Probe
|
back to top
SR759 AC Current Probe
Specifications:![]() The SR759 probe is a range selectable probe that offers four switch selectable ranges: 1, 10, 100 or 1000A. This probe has a voltage output proportional to the current measured in the jaw of the probe. Nominal Range: 1A, 10A, 100A, 1000A Measurement Range: 1mA to 1200A Output Signal: 1A: 1000mV 10A: 100mV 100A: 10mV 1000A: 1mV/Aac Accuracy: Range dependent. See datasheet for details. Frequency Range: 30 to 3kHz Max. Conductor Size: 2.05 inch (52mm) Part Number: 24661400 Request Datasheet for SR759 current probe |
back to top
JM875 AC Current Probe
Specifications:![]() The JM875 is a high performance AC Current Probe provides an accurate voltage output proportional to the measured current (1mV/A, 10mV/A or 100mV/A). Nominal Range: 30A, 300A, 3000A Measurement Range: 1A to 3200A Output Signal: 30A: 100mV 300A: 10mV 3000A: 1mV Accuracy: Range dependent. See datasheet for details. Frequency Range: 30 to 5kHz Max. Conductor Size: Cable - 2.52 inch (64mm); Bus bar: 1.97 x 5.31 inch (50mm x 135mm); 2.52 x 3.94 inch (64mm x 100mm) Part Number: 24661500 Request Datasheet for JM875 current probe |
back to top
FP300A Flexible Current Probe
Specifications:![]() The FP300A is a flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used. Measurement range is 5 to 300A. Measurement Range: 5A to 300A Output Signal: 10mV/A Accuracy: 1% of Reading Frequency Range: 10 to 20kHz Minimum Bend Radius: 0.75 inch (19mm) Part Number: 24661600 Request Datasheet for FP300A current probe |
back to top
FP3000A Flexible Current Probe
Specifications:![]() The FP3000A is a low cost AC current measurement probe, composed of a flexible sensor and an electronic module with a 14" double insulated cable. Measurement Range: 5A to 3000A Output Signal: 10 mV/A for 5A to 3000A 1mV/A for 50A to 3000A Accuracy: 1% of Reading +/- 500mA Frequency Range: 40 to 5kHz Maximum Conductor Size: 7.6 inch (193mm) Part Number: 24661700 Request Datasheet for FP3000A current probe |
back to top
FP6000A Flexible Current Probe
Specifications:![]() The FP6000A is a flexible AC current probe composed of a flexible sensor and an electronic module. The flexible sensor permits measurements on conductors where standard clamp-on probes cannot be used. Measurement Range: 5A to 6000A Output Signal: 1mV/A / 0.1mV/A (see note below) Accuracy: 1% of Reading Frequency Range: 10 to 20kHz Sensor Length: 24 inch (610mm) Part Number: 24441620 Note: 0.1mV/A scale requires 1000A minimum. Request Datasheet for FP6000A current probe |
back to top




The MN255 is a high sensitivity probe with voltage outputs (100mV/A and 10mV/A) and combine two switch-selectable ranges of 20A and 200A, thus permitting accurate measurements at low and high levels.